Viscosity Meters ALPHA Series |
Viscosity Meters, ALPHA Series
|
ALPHA R
|
When testing the viscosity of fluids, it's important that your equipment has fast and
accurate readings. The new Alpha Series viscosity meters distributed by Thermoline
Scientific ensure users have precise measurements in seconds. The units are easy to
use and very economical to buy.
There are three models available which cover viscosity ranges from 20 to 106 000 000
centipoise, all supplied complete with a comprehensive user guide and set of spindles.
Optional adaptors are also available should you require readings outside the range of
the standard spindles.
Main Features
Data displayed:
Selected speed (r.p.m.)
Selected spindle (SP)
Viscosity reading (cP ) (mPa·s)
Percentage of full scale (%)
- Relative and absolute viscosity.
- Unit converter SI to CGS.
- AUTO-TEST with sound and visual malfunction alarm.
- AUTO-RANGE function.
- User-enabled calibration.
- 8 language options.
Standard delivery: The equipment is supplied
complete with standard spindles (4 spindels for
L model, and 6 spindles for R and H models),
viscometer stand and spindle protector.
Technical Details
- Precision: ± 1% of full scale.
- Resolution:
Using low viscosity adapter: 0.01
For lower than 10,000 viscosity cP: 0.1
For viscosity equal to or above 10,000 cP: 1
- Repeatability: 0.2%
- Supplied at 100-240 VAC, 50/60 Hz
|
| Code |
Model |
Measuring Range (cP) |
Speed (RPM) |
Number of Speeds |
| V100003 |
ALPHA L |
20 ~ 2,000,000 |
0.3 ~ 100 |
18 |
| V100002 |
ALPHA R |
100 ~ 13,000,000 |
0.3 ~ 100 |
18 |
| V100001 |
ALPHA H |
200 ~ 106,000,000 |
0.3 ~ 100 |
18 |
Viscosity Meter Adaptors
|
|
Low Viscosity Adaptor
|
Low Viscosity adapters are used with the rotational viscometers to perform accurate and reproducible measurements on low viscosity materials, from 1 cP (mPa·s), as well as shear rate and shear stress determinations. It is supplied with spindle.
Technical features
Sample volume: from 16 to 18 ml.
Removable stainless steel sample container easily cleaned.
PT100 probe to determine the sample temperature with accuracy (optional).
Viscosity range with LCP and LCP/B
Viscometer model L - 1 - 2,000 cP
Viscometer model R - 5 - 21,333 cP
|
|
Heldal Unit Adaptor
|
Accessory designed for viscosity measurements of non-flowing substances.
In these materials the viscosity cannot be measured by standard methods and spindles due to cavitation effect around the spindle. We recommend using the HELDAL
unit and T-bar spindles for comparative measurements on non-flowing substances.
A Fungilab viscometer is mounted on the Heldal unit, and it restricts measuring head to smoothly run up and down within pre-established limits, allowing constant contact
between T-bar spindle and test sample thanks to the helical line described.
- Easy to use, install and clean.
- Supplied with motor, 6 T-shaped spindles and carrying case.
- Compatible with all FUNGILAB rotational viscometers.
|
Click to download PDF Product Sheet
|